Restricted to use within the memory area range of Pre-V1 CPU Units. ![]() *4.Cannot be used with 20-point CPU Units. Note: The above operations were not supported by ZEN Support Software versions lower than 2.0. If "C (clear)" is set, the display function (D) will be deleted from the program. If "DAT1: day/month" is set, CHR (character designation) will be set. *3.When reading out the program from the ZEN, the following items will be determined based on the display function (D) settings contained in the program. ![]() Note: The above operations were not supported in ZEN versions prior to 1.1. If "C (clear)" is set, the LCD display will appear as and the display function will not operate. *2.The setting for a display bit (D) will appear as follows: If "DAT1: day/month" is set for display, the LCD display will show T# and the display function will not operate. Version 2 of the ZEN includes Economy-type CPU Units and Communications-type CPU Units. Its development has drawn on OMRONs advanced control technology and expertise in manufacturing various types of controllers. With "-V2" CPU Units, "V03.00" will be displayed as the system software version. The ZEN is a compact and highly functional controller that can be used to easily automate small-scale applications. ![]() *1.With LCD-type CPU Units, the system software version can be read by selecting Other/System information from the menu.